Eicom's HTEC-500 Model Specifications

System

The degasser, pump and ECD are mounted in a temperature controlled cabinet. A manual injector is also included.
System Control Integrated central control
Materials in contact with solvents PEEK and FEP, Metal Free Materials
Flow line pressure resistance 20 MPa

Detector

(1st channel) 

Amperometric DC mode

Detector

(2nd channel) Option

Coulometric ECD or UV/Vis detection
Dimensions  250 (w) x 399 (h) x 365 (d) mm/approx 10" x 16" x 14.5" 
Weight 18 kg with amperometric detector cell/40 lb 

Electrochemical Detection

(1st channel)

Expandable for second channel with model EPC-510
Principle Amperometric DC mode
Applied potential range 0 to +/- 2000 mV, 1 mV steps
Integrator output range Auto-zero point +/- 5 V, 0.1 nA/1 mV
Auto-zero working range +/- 500 nA
Detector Cell Easy Open/Close with constant pressure system
Working Electrode Exchangeable disk
Standard Working Electrode Graphite, S/N 250% improved from glassy carbon
Working Electrode Options Platinum, Modified Gold, Pure Graphite, Glassy Carbon, Silver
Surface Volume of Working Electrode Changeable, 25 or 50 µm thickness with 3.5 or 7 mm width
Reference Electrode Material Ag/AgCl
Counter Electrode Material Stainless Steel 316
Time Constant Filter 1.0/1.5/3 min
Noise Level Less than 3 pA with dummy flow of R-W 1 MΩ R-C 2 MΩ at 0 mV                 

High Performance Pump
Single stroke replacement volume 4 µl, Φ2 x1.3 mm stroke
Principle Isocratic, reciprocal dual piston pump
Pulsation control Controllable On/Off capability. Computer programmed auto-quenching pulse system by variable stroke speed drive during each stroke.
Pistons material Sapphire Glass
Check valves Φ1/16" two check valves at the outlet and a single valve at the inlet
Piton seal High density polyethylene, Teflon® also available
Flow rate range 0 to 750 µl/min
Pulse damper Not required, not included
Error monitor Over pressure limit error, check valve error, motor error

Thermoregulation
Temperature control range 20-45°C at 25°C ambient        
Control procedure Peltier element to both cool and heat                                                                                        

Solvent Degassing Unit
Principle   Online      
Channel Two
Internal volume Ch1 300 µl/Ch2 7.5 ml

Communication All connectors are easy to access outside the component
ECD integrator out Analog, 0.1 nA = 1 mV, 10 V full range
Pump pressure monitor out Analog, 10 MPa = 100 mV
Temperature monitor out Analog 10°C = 100 mV.
Pump error out 1.0 sec contact closure signal out. Works to stop autosampler.
Stop/Run outer trigger in Stop/Run ECD and pump unit. 0.5 sec contact closure signal in. Works for auto stop and auto start. Main power required to be on to receive the signal.
Auto-zero trigger in Runs auto-zero, 0.5 sec contact closure signal in
Manual injector switching signal in After receiving the signal, the delay out sends signal out.
Inject Signal in After receiving the signal, the delay out sends signal out. Works to communicate with an autosampler.
Delay out 2 ports. 0 and 3 sec delay with 1.0 sec contact closure signal.

The specification are subject to change without notice.